COOLING FANS
Chilled and stationary welding machines are chilled and transformer cooled Sewing It is used for chin and transformer cooling of welding machines.Water cooling with flange spot welding machines is very important.First of all, it ensures that your production is of good quality and fast, it prevents welder malfunctions and excessive current draw without warming up your spot machine.As a consumable material, it provides much more durable and efficient use of spot welding tips that you pay in serious amounts.Spot cooler CHILLERS Our device is actively cooling with the cooling compressor, so it is not only related to fan and radiator-operated devices Thanks to its superior properties, it will amortize itself shortly
Technical Details |
SNT 01 COOLING FAN MINI M -1 |
---|---|
Dimensions |
70 x 40 x 50 (h) cm |
Cooling capacity |
780 kcal/h - 3100 Btu/h / ( 20 ºC Water Temperature ) |
Water Using Temperature | 5 - 30 ºC arası |
Kompressor Type and Power |
Hermetical Type Ecovat 1/4
Hp |
Water Pump |
24 volt dc brushless |
Water Pump Capacity |
20 L/dk. 1 Bar |
Water Tank |
PVC 10 Lt. |
Water Control |
Dijital Termometre Termostat / Water FlowControl/ Buzzer |
Total Power and Voltage |
0,45 kW / 220 V 50Hz |
Soğutucu Gaz Cinsi |
R 134 |
Technical Details |
SNT-02 COOLING FAN M-2 |
Dimensions |
70 x 40 x 50 (h) cm |
Cooling capacity |
1300 kcal/h - 5200 Btu/h / ( 20 ºC Water Temperature ) |
Water Using Temperature |
5 - 30 ºC between |
Water Pump Capacity |
Hermetical Type Ecovat 1/2 Hp |
Water Pump |
24 volt dc brushless |
Total Power and Voltage |
20 L/dk. 1 Bar |
Water Tank |
PVC 10 Lt. |
Teknik Detay |
SNT-03 COOLING FAN BIG SIZE M-3 |
Dimensions |
60 x 53 x 87 (h) Cm. |
Cooling capacity |
2500 k cal. 2,9 KW ( 20 ºC Water temperature ) |
Water Using Temperature |
5 - 30 ºC between |
Water Pump Capacity |
Hermetical Kompressor 1 Hp |
Water Pump |
150 W BRONZ or 24 volt dc brushless |
Water Tank |
PVC 30 Lt. |
Water control |
Digital Control Electrical Panel |
Total Power and Voltage |
1,5 kW / 220 V 50Hz |
Cooling Gas Type |
R 407 |